Imagen

X02-04MB - Purga Automática Serie X02 FRLs - Wilkerson

¿Tienes una duda? 

Llámanos al +8183545649 o da clic en el botón de contacto para mandarnos un email.

Atributos

Métrica de Presión de Operación Máxima
13.8 Bar
Presión de Operación Máxima
200 PSIG
Peso
1.68 lb
Break Quantity
1
Paquete Opcional/Cantidad por Caja
1
Rango de Temperatura
32°F to 150°F (0°C to 65.5°C)
Puerto
1/2"

Detalles

Description

Metal bowl

Features

  • Metal bowl
  • 5 oz. bowl
  • Fully automatic, float operated
  • Full 1/2" NPT drain inlet
  • Quick-disconnect clamp ring for easy bowl removal when servicing
  • No electrical connections
  • Easily installed

How It Works

As liquid contaminants collect in the bowl, they raise a closed-cell cellular float. When the liquid level reaches a given point, the float triggers a mechanism which pilots line pressure against a large area piston or diaphragm which snaps open the drain valve. The contaminants are discharged from the drain orifice at line pressure. As the liquid level falls, the pilot valve closes, line pressure against the piston/diaphragm returns to atmosphere and the drain valve snaps closed.

Recursos